taps at the water outlet elbow

Post by markattard »

Since the threads at the water outlet elbow are anything but what they should be, I think I nead to tap them through, any idea please what taps should I use?
bmcecosse
Minor Maniac
Posts: 46561
Joined: Wed Feb 16, 2005 11:24 pm
Location: ML9
MMOC Member: No

Post by bmcecosse »

Water outlet elbow ? Do you mean where the heater tap bolts down on the back end of the cylinder head ? If so - these holes are 1/4" unf - so either go up to 5/16", or 8 mm - since metric stuff is more easily obtainable these days. Probably need to run a drill through the elbow fixing holes too.
ImageImage
Image
rayofleamington
Moderator
Moderator
Posts: 7679
Joined: Fri Nov 01, 2002 2:55 pm
Location: LEAMINGTON SPA
MMOC Member: No

Post by rayofleamington »

bear in mind that if you go for a bigger thread the head size will probably foul the heater-tap body.
Ray. MMOC#47368. Forum moderator.

Jan 06: The Minor SII Africa adventure: http://www.minor-detour.com
Oct 06: back from Dresden with my Trabant 601 Kombi
Jan 07: back from a month thru North Africa (via Timbuktu) in a S3 Landy
June 07 - back from Zwickau Trabi Treffen
Aug 07 & Aug 08 - back from the Lands End to Orkney in 71 pickup
Sept 2010 - finally gave up breaking down in a SII Landy...
where to break down next?
2013... managed to seize my 1275 just by driving it round the block :(
Kevin
Moderator
Moderator
Posts: 7592
Joined: Thu Feb 14, 2002 12:00 am
Location: Watford, Hertfordshire.
MMOC Member: No

Post by Kevin »

By elbow I bet you mean the thermostat housing, can you be more specific.
Cheers

Kevin
Lovejoy 1968 Smoke Grey Traveller (gone to a new home after13 years)

Herts Branch Member
Moderator MMOC 44706
Packedup
Minor Legend
Posts: 1429
Joined: Tue Aug 02, 2005 1:40 am
MMOC Member: No

Post by Packedup »

If it's the heater outlet, try longer bolts and not too much tightening. I've stripped a couple of these in the past, and found using longer bolts and just nipping them up enough to stop any leaks has got round the problem nicely :)

Same probably goes for the stat housing, but I can't remember if I've ever stripped those threads or not - Too many memories of having to saw the alloy off to remember much else about the job...
Kevin
Moderator
Moderator
Posts: 7592
Joined: Thu Feb 14, 2002 12:00 am
Location: Watford, Hertfordshire.
MMOC Member: No

Post by Kevin »

Too many memories of having to saw the alloy off to remember much else about the job...
A common type of problem mainly through previous owners lack of antifreeze, although I think the brass ones from one of the specialists would resolve the problem.
Cheers

Kevin
Lovejoy 1968 Smoke Grey Traveller (gone to a new home after13 years)

Herts Branch Member
Moderator MMOC 44706
bmcecosse
Minor Maniac
Posts: 46561
Joined: Wed Feb 16, 2005 11:24 pm
Location: ML9
MMOC Member: No

Post by bmcecosse »

If it's the threads where the thermostat housing is bolted on - these are 3/8" UNC in the head - virtually the same as 3/8" Whitworth.
And yes, point taken about the bigger heads fouling if it's the heater tap - use Allen cap head screws to get round this problem.
ImageImage
Image
wanderinstar
Minor Addict
Posts: 833
Joined: Sun Jun 13, 2004 12:47 pm
Location: Colne Lancs.
MMOC Member: No

Post by wanderinstar »

But Roy, would you get an allen key into the one on the left, looking from front of engine, under the outlet. Seem to remember I had to lift the valve as I was unscrewing it to get nut off.
Ian.
bmcecosse
Minor Maniac
Posts: 46561
Joined: Wed Feb 16, 2005 11:24 pm
Location: ML9
MMOC Member: No

Post by bmcecosse »

Dunno Ian - many different types of valve. There will be a way!
ImageImage
Image
Kevin
Moderator
Moderator
Posts: 7592
Joined: Thu Feb 14, 2002 12:00 am
Location: Watford, Hertfordshire.
MMOC Member: No

Post by Kevin »

Yes it would be possible with the ealier type gate valve but probably not with the later type valve.
Cheers

Kevin
Lovejoy 1968 Smoke Grey Traveller (gone to a new home after13 years)

Herts Branch Member
Moderator MMOC 44706
Post Reply