Just get a non-polarized capacitor and connect it across the connections to the points. What it does is it allows the high frequency harmonics created by the sparking across the capacitor and shorts them out on the other terminal, thus removing a lot of the 'sparky bits' which reduces the oxidisation on the sparking terminals and extends their life considerably. This is why we have an ignition condenser across the points terminals.
an ignition supression capacitor should do the trick, or just get a 0.1 microfarad one.
SU Petrol Pump Capacitator
Forum rules
By using this site, you agree to our rules. Please see: Terms of Use
By using this site, you agree to our rules. Please see: Terms of Use
-
- Minor Legend
- Posts: 3204
- Joined: Tue Feb 12, 2002 12:00 am
- Location: S E London
- MMOC Member: No
capacitor
The difference is that the ignition capacitor is designed in to
the distributor. Where exactly are you going to fit the new
capacitor in the pump?? I think it would have to hang outside
which might give some problems?? all the later pumps have double
contacts and seem to be quite reliable if the points are cleaned
very occasionally.
the distributor. Where exactly are you going to fit the new
capacitor in the pump?? I think it would have to hang outside
which might give some problems?? all the later pumps have double
contacts and seem to be quite reliable if the points are cleaned
very occasionally.
Willie
[img]http://i39.photobucket.com/albums/e197/wuzerk/mo9.jpg[/img]
[img]http://i39.photobucket.com/albums/e197/wuzerk/mo9.jpg[/img]
-
- Moderator
- Posts: 5109
- Joined: Mon May 20, 2002 1:00 am
- Location: Stoke-on-Trent, Staffordshire, UK
- MMOC Member: No
The 0.1 microfarad capacitors are quite small and should fit easily behind the cap (although I have not checked) as they are about the same size as your finger nail and have stiff wire legs to bend and hold them in place.
It would not matter if it did hand outside the cap as it is not dangerous and it will not stop functioning even if it is submerged in water.
It would not matter if it did hand outside the cap as it is not dangerous and it will not stop functioning even if it is submerged in water.
-
- Minor Legend
- Posts: 3204
- Joined: Tue Feb 12, 2002 12:00 am
- Location: S E London
- MMOC Member: No
capacitor
Yes, worth a try but the moving contact on the pump has quite
a long travel so the capacitor lead to this side will have to be
super flexible( like the braided wire in the distributor from the
side contact to the moving plate).
a long travel so the capacitor lead to this side will have to be
super flexible( like the braided wire in the distributor from the
side contact to the moving plate).