Cable size

Discuss Electrical problems here.
Forum rules
By using this site, you agree to our rules. Please see: Terms of Use
Post Reply
paul1957
Minor Friendly
Posts: 45
Joined: Mon Sep 04, 2017 4:55 pm
MMOC Member: Yes

Cable size

Post by paul1957 »

Hi guys what size cable in amps goes from the ignition switch to the coil and from the ignition switch to the starter solenoid the car is negative earth and has a alternator conversion
Regards Paul
oliver90owner
Minor Legend
Posts: 1904
Joined: Thu May 12, 2016 6:33 am
MMOC Member: No

Re: Cable size

Post by oliver90owner »

The coil will normally take no more than about 4A with points closed (ie resistive current determined by battery voltage (V) and coil resistance (R) according to Ohm’Law which is V=IR where the current (I) is calculated as Amps).

The gauge of the wire would not need to be in excess for a continuous load so a gauge suitable for 8A would be more than adequate. The current when the engine is running will be considerably reduced due to the inductive action of the continual opening and closing of the circuit by the operation of the contact points in the distributor.
paul1957
Minor Friendly
Posts: 45
Joined: Mon Sep 04, 2017 4:55 pm
MMOC Member: Yes

Re: Cable size

Post by paul1957 »

Thanks for your reply 👍
paul1957
Minor Friendly
Posts: 45
Joined: Mon Sep 04, 2017 4:55 pm
MMOC Member: Yes

Re: Cable size

Post by paul1957 »

Would electronic ignition make a difference