ignition problem
Forum rules
By using this site, you agree to our rules. Please see: Terms of Use
By using this site, you agree to our rules. Please see: Terms of Use
ignition problem
My 1949 2 door MM UK built Minor has a problem that has got me stumped. it starts and runs good but after running it 5-10 KMs to warm it, I turn the ignition off and then try to restart it. The engine turns over but no ignition. I turn it off and wait 20 odd minutes and try again with no problem. New Coil and condenser fitted and both just warm. Any ideas please
-
myoldjalopy
- Minor Legend
- Posts: 3570
- Joined: Tue Jan 29, 2013 10:32 pm
- Location: Kernow
- MMOC Member: Yes
Re: ignition problem
Did you have this problem with the old coil and condensor as well?
- svenedin
- Minor Legend
- Posts: 4989
- Joined: Fri Aug 29, 2014 9:27 am
- Location: Surrey
- MMOC Member: Yes
Re: ignition problem
Where did the coil and condenser come from? Some new parts are of such poor quality that they can fail in minutes.
Stephen
Stephen
1969 1098cc Convertible “Xavier” which I have owned since 1989.
Stephen
Stephen
- geoberni
- Minor Maniac
- Posts: 5343
- Joined: Fri Aug 04, 2017 11:19 am
- Location: North Leicestershire
- MMOC Member: Yes
Re: ignition problem
Were the new Coil and Condenser fitted because of this problem, or just before it appeared.edhouse1 wrote: ↑Mon Nov 23, 2026 9:22 am My 1949 2 door MM UK built Minor has a problem that has got me stumped. it starts and runs good but after running it 5-10 KMs to warm it, I turn the ignition off and then try to restart it. The engine turns over but no ignition. I turn it off and wait 20 odd minutes and try again with no problem. New Coil and condenser fitted and both just warm. Any ideas please
At the moment, it sounds like the Coil failing when warm.
If you have a multimeter, warm it up to reproduce the problem and then continuity check the Coil, between all 3 terminals, the 2 tags and the HT output.